Elevator
An elevator is a Transport device used to move goods or people vertically. In British English and other Commonwealth Englishes, elevators are known more commonly as lifts, although the word elevator is familiar from American movies and Television shows, just as some Americans are aware of lift from imported entertainment. Other languages may have loanwords based on either elevator (e.g. Japanese) or lift (e.g. Cantonese). Because of wheelchair access laws, elevators are often a requirement in new buildings with multiple floors. HistoryElevators began as simple Rope or Chain hoists. An elevator is essentially a platform that is either pulled or pushed up by a mechanical means. A modern day elevator consists of a cab (also called a "cage" or "car") mounted on a platform within a enclosed space called a shaft or more correctly a "hoistway". In the past elevator drive mechanisms were powered by steam and water hydraulic pistons.In a "traction" elevator, cars are pulled up by means of rolling steel ropes over a deeply grooved Pulley, commonly called a sheave in the industry. The weight of the car is balanced with a counterweight. The friction between the ropes and the pulley furnishes the traction which gives this type of elevator its name. Hydraulic elevators use the principal of Hydraulics to pressurize an above ground or inground piston to raise and lower the car. Roped Hydraulics use a combination of both ropes and hydraulic power to raise and lower cars. Recent innovations include permanent earth magnet motors, machineroom-less rail mounted gearless machines, and microprocessor controls. Which technology is used in new installations depends on a variety of factors. Hydraulic elevators are cheaper, but installing cylinders greater than a certain length becomes impractical for very high lift hoistways. For buildings of much over seven stories, traction elevators must be employed instead. Hydraulic elevators are usually slower than traction elevators. In 1823, an "ascending room" made its debut in London.
In 1853, Elisha Otis introduced the safety elevator, which prevented the fall of the cab if the cable broke. The design of the OTIS safety is somewhat similar to one type still used today. It consists of knurled roller(s) that lock the elevator to its guides should the elevator descend at an excessive speed, which is monitored by a governor device. On March 23, 1857 the first Otis elevator was installed at 488 Broadway in New York City. The first elevator shaft preceded the first elevator by four years. Construction for Peter Cooper's Cooper Union building in New York began in 1853. An elevator shaft was included in the design for Cooper Union, because Cooper was utterly confident a safe passenger elevator would soon be invented; the shaft however was circular because Cooper felt it was the most efficient design. Later Otis designed a special elevator for the school. Today the Otis Elevator Company, now a subsidiary of United Technologies Corporation, is the world's largest manufacturer of vertical transport systems, followed by Schindler, Thyssen-Krupp and Kone, in order. The first electric elevator was built by Werner von Siemens in 1880. The safety and speed of electric elevators were significantly enhanced by Frank Sprague. The development of elevators was led by the need for movement of large amounts of raw materials including Coal and Lumber from hillsides. The technology developed by these industries and the introduction of steel beam construction worked together to provide the need for the passenger and freight elevators we use today. Modern elevator constructionToday, elevators are built under strict supervision of the Building Codes. Model Codes which are the standard in most US and Canadian jurisdictions require compliance with the American Society of Mechanical Engineers' standards for the installation, maintenance, and inspection of elevators. In addition other related standards are likely required to be complied with as specified by Local Authorities Having Jurisdiction.Elevators are generally sold in prepackaged components which are inherently non-proprietary. All of the four major manufacturers sell proprietary Microprocessor controls. Each manufacturer provides similar product designs, and the overiding issue for purchase is usually price and availablility. In the case of renovations, the use of non-proprietary controls has become a large part of that business because it allows the owner to offer the maintenance contract to multiple bidders rather than accept a single manufacturer for the life of the elevator which can be more than 30 years. In some large campus type properties, the use of non-proprietary equipment in new construction has replaced the standard prepackaged product. Non-proprietary systems generally have a higher up front cost, but may be offset by allowing the owner to control the long term costs over the life of the elevator. In some locations, the shaft and parts of the cab are made of transparent material for specialized "Scenic elevators." This allows riders to see outside the cab as they travel on the elevator. Some locations take advantage of this transparent material by placing the elevators along the walls of their building. This allows riders to see the outdoor environment as the cab runs along the side of the buildings. Today, all new elevators are computer-controlled and microprocessor based. This allows the elevator system to place cabs where they are most needed in the interest of smooth running, with behavior based on analysis of building use called "Traffic Studies." Traffic Studies are done by professional elevator consultants who use specialized tools to determine the optimum size, speed and number of elevators for a building based on its peak use periods. Computer control also permits greater control of access to various floors of a building after hours and on weekends. Methods of access control include card readers, keys, and access codes entered into the control panel of the elevator. Elevators are usually installed in a building during construction. Renovations may consist of replacements for hoistway (floor landing) doors, car doors, interior cab finishes, controls, hoist machines, hydraulic pistons and hall fixtures. In many instances the upgrading of components may require additional code compliance, these issues should be reviewed with an elevator consultant prior to the purchasing of new materials. Elevator safetyElevators are inherently safe. Their safety record, that of moving millions of passengers every day, without incident, is unsurpassed by any other vehicle system. Recently, however, hydraulic elevators built prior to a code change in 1972 have been found to be subject to possible catastrophic failure. The code had previously required only single-bottom hydraulic cylinders; in the event of a breach of the cylinder, an uncontrolled fall of the elevator might result. This concern is reflected in the ASME A17.1 Maintenance of Hydraulic elevators section of the 2000 edition to require verification of system integrity in underground hydraulic elevator cylinders. Because it is impossible to verify the system completely without a pressurized casing (as described below), it is necessary to actually remove the piston to inspect it. The cost of removing the piston is such that it makes no economical sense to re-install the old cylinder, and therefore it is logically necessary to install a new elevator.In addition to the safety concerns for older hydraulic elevators, there is risk of leaking hydraulic oil into the aquifer and causing potential environmental contamination. This has led to the introduction of PVC liners (casings) around hydraulic cylinders which can be monitored for integrity. Recent innovations called machineroomless elevators may soon make the use of hydraulic elevators obsolete. Elevators are regulated by the Consumer Product Safety Commission and are subject to the provisions of that regulation body. In 2004 the CPSC published a consumer alert about the safe use of escalators. Uses of elevatorsPassenger serviceA passenger elevator is designed to carry people and small packages.Passenger elevator capacityPassenger elevators capacity is related to the available floor space. Generally passenger elevators are available in typical capacities from 1,500 to 5,000 lb (680 to 2,300 kg) in 500 lb (230 kg) increments. Generally passenger elevators in buildings 4 stories or less are hydraulic, however concerns with hydraulic elevators in recent years have limited their installations. In buildings up to 10 stories, electric elevators are likely to have speeds up to 300 ft/min (1.5 m/s), and above 10 stories speeds begin at 500 ft/min (2.5 m/s) up to about 1200 ft/min (6 m/s).Types of passenger elevatorsPassenger elevators may be specialized for the service they perform, including: Hospital emergency (Code blue), front and rear entrances, double decker (2 cars on top of one another), and other uses. Cars may be ornate in their interior appearance, may have audio visual advertising, and may be provided with specialized recorded voice instructions. The concern for entrapping passengers requires all elevators to have communication connection to an outside 24 hour emergency service, automatic recall capability in a fire emergency, and special access for fire department use in a fire. Elevators are not an acceptable means of escape during a fire and should not be used by the Public for this purpose. Signs are required in most all US Jurisdictions to "USE STAIRS IN CASE OF FIRE." Residential elevators may be small enough for one person while some are large enough for more than a dozen. Wheelchair, or Platform lifts, a specialized type of elevator designed to move a Wheelchair 6 ft (2 m) or less, often can accommodate just one person in a wheelchair at a time with a maximum load of 750 lb (340 kg).Freight elevatorsA freight elevator is an elevator designed to carry goods, rather than passengers. (Passengers often accompany the freight, however.) Freight elevators are exempt from some of the ASME A17.1 code requirements, as defined by the words "not for public use." Freight Elevators or Service elevators may be exempt from some of the requirements for fire service. However, new installations would likely be required to comply with these requirements. Freight elevators are generally required to display a written notice in the car that the use by passengers is prohibited, though certain freight elevators allow dual use through the use of an inconspicuous riser. Freight elevators are typically larger and capable of carrying heavier loads than a passenger elevator, generally from 5,000 to 10,000 lb (2,300 to 4,500 kg). Freight Elevators may have manually operated doors, and often have rugged interior finishes to prevent damage while loading and unloading. Although hydraulic freight elevators exist, electric elevators are more energy efficient for the work of freight lifting. A small freight elevator is often called a dumb waiter (see next section), often used for moving of small items such as dishes in a 2-story kitchen or books in a multi-story rack assembly. Passengers are never permitted on dumbwaiters. Dumbwaiters and other material lifts are required to conform to the related sections of the ASME A17.1 code in most U.S. and Canadian Jurisdictions. A specialized type of freight elevator is an Automobile Lift, used to move automobiles around a parking garage or other facility. These are material lifts by definition and are exempt from the ASME A17.1 requirements, but may have to comply with the requirements of ALI ALCTV if provided for in the local jurisdiction. Stage and Orchestra lifts are specialized lifts for use in the performing arts, and are exempt from the ASME A17.1 requirements. Local Jurisdictions may govern their use, installation and testing, however they are often left out of local code enforcement provisions due to their infrequent installation.Dumb waiterA small box elevator designed for the carriage of lightweight freight is called a dumb waiter (or dumbwaiter). Dumbwaiters are required to comply with ASME A17.1 in most US and Canadian Jurisdictions. Dumbwaiters are generally driven by a small electric motor with a counterweight and their capacity is limited to about 750 lb (340 kg). They may also be hand operated using a roped pulley. Dumbwaiters are used extensively in the restaurant business (hence the name) and may also be used as book lifts in libraries, or to transport mail or similar items in an office tower.Material handling beltsA different kind of elevator is used to transport material. It generally consists of an inclined plane on which a conveyor belt runs. The conveyor often includes partitions to prevent the material from sliding backwards. These elevators are often used in industrial and agricultural applications. When such mechanisms (or spiral screws or pneumatic transport) are used to elevate grain for storage in large vertical silos, the entire structure is called a Grain elevator.Types of elevator hoist mechanismsIn general, there are three means of moving an elevator:Traction elevators
Hydraulic type
Climbing elevatorA climbing elevator is a self-ascending elevator with its own propulsion. The propulsion can be done by an electric or an combusting engine. Climbing elevators are used in guyed masts or towers, in order to make easy access to parts of these constructions, such as flight safety lamps for maintenance.PaternosterA special type of elevator is the Paternoster, a constantly moving chain of boxes. A similar concept moves only a small platform, which the rider mounts while using a handhold and was once seen in multi-story industrial plants.Controlling elevatorsGeneral controlsA typical modern passenger elevator will have:
Some elevators may have one or more of the following:
Other controls, which are generally inaccessible to the public (either because they are key switches, or because they are kept behind a locked panel, include:
Controls in early elevators
Floor numbering
The elevator algorithmThe Elevator algorithm is a simple Algorithm by which a single elevator can decide where to stop is:
Computer dispatchedEfficiencies of multiple elevators installed in an office building may increase if a central dispatcher is used to group passengers going to the same floor to the same elevator. In buildings with these computer-dispatched elevator system, passengers key in their destination floor in a central dispatch panel located at the building lobby. The dispatch panel will then tell the passenger which elevator to use. Inside the elevator there is no call button to push (or the buttons are there but they cannot be pushed, they only indicate stopping floors). Manufacturers of such systems claim that average travelling time can be reduced by up to 30%. Sometimes, however, one person enters the destination for a large group of people going to the same floor. The dispatching algorithm is usually unable to completely cater for the variation, and late comers may find the elevator they're assigned to is already full.uyuSpecial operating modesUp peakDuring Up Peak mode, elevator cars in a group are recalled to the lobby to provide expeditious service to passengers arriving at the building, most typically in the morning as people arrive for work or at the conclusion of a lunch-time period. Elevators are dispatched one-by-one when they reach a pre-determined passenger load, or when they have had their doors opened for a certain period of time. The next elevator to be dispatched usually has its hall lantern or a "this car leaving next" sign illuminated to encourage passengers to make maximim use of the available elevator system capacity.The commencement of Up Peak may be triggered by a time clock, by the departure of a certain number of fully loaded cars leaving the lobby within a given time period, or by a switch manuallly operated by a building attendant. Down peakDuring Down Peak mode, elevator cars in a group are sent away from the lobby towards the highest floor served, after which they commence running down the floors in response to hall calls placed by passengers wishing to leave the building. This allows the elevator system to provide maximum passenger handling capacity for people leaving the building.The commencement of Down peak may be triggered by a time clock, by the arrival of a certain number of fully loaded cars at the lobby within a given time period, or by a switch manually operated by a building attendant. Sabbath serviceIn areas with large populations of observant Jews, one may find a "Sabbath Elevator". In this mode, an elevator will stop automatically at every floor, allowing people to step on and off without having to press any buttons. Regenerative braking is also disabled if it is normally used, shunting energy collected from downward travel, and thus the gravitational Potential energy of passengers, into a Resistor network. This prevents violation of the Sabbath prohibition against doing useful work.Independent serviceIndependent Service is a special service mode found on most elevators. It is activated by a key switch either inside the elevator itself or on a centralised control panel. When an elevator is placed on independent service, it will no longer respond to hall calls. (In a bank of elevators, traffic would be rerouted to the other elevators, while in a single elevator, the hall buttons will be disabled). The elevator will remain parked on a floor with its doors open until a floor is selected and the door close button is held until the elevator starts to travel. Independent Service is useful when transporting large goods or moving groups of people between certain floors.StandardsThe mechanical, electrical and operational design of elevators are dictated according to various standards (aka elevator codes), which may typically be international, national, state, regional or city based. Where once many standards were prescriptive, specifying exact criteria which must be complied with, there has been a shift towards more performance-based standards where the onus falls on the designer to ensure that the elevator meets or exceeds the standard.Some of the national elevator standards include:
Because an elevator is part of a building, it must also comply with standards relating to earthquake resilience, fire standards, electrical wiring rules and so forth. Additional requirements relating to access by disabled persons, may be mandated by laws or regulations such as the Americans with Disabilities Act US and Canadian elevator standard specificsPassenger elevators are required to conform to the American Society of Mechanical Engineer's Standard A17.1 Safety Code for Elevators and Escalators in most US and Canadian Jurisdictions (In Canada the document is the CAN/CSA B44 Safety Standard which was harmonized with the US version in the 2000 edition.) In additon passenger elevators may be required to conform to the requirements of A17.3 for existing elevators where referenced by the Local Jurisdiction. Passenger elevators are tested using the ASME A17.2 Standard. The frequency of these tests is mandated by the Local Jurisdiction, which may be a town, city, or state standard.Passenger elevators must also conform to many ancilliary building codes including the Local or State building code, National Fire Protection Association standards for Electrical, Fire Sprinklers and Fire Alarms, Plumbing codes, and HVAC codes. In addition passenger elevators are required to conform to the American's with Disabilities Act and other State and Federal civil rights legislation regarding accessibility. Residential elevators are required to conform to ASME A17.1 Platform and Wheelchair lifts are required to comply with ASME A18.1 in most US Jurisdictions. Unique elevator systemsThe gateway arch
The Gateway Arch in Saint Louis, Missouri has a unique elevator system which carries passengers from the visitors center underneath the Arch to the observation deck at the top of the structure. Called a tram or tramway, people enter this unique Tramway much as one would enter an ordinary elevator, through double doors. Passing through the doors the passengers in small groups enter a horizontal cylindrical compartment containing seats on each side and a flat floor. A number of these compartments are linked to form a train. These compartments each individually retain an appropriate level orientation by tilting while the entire train follows curved tracks up one leg of the arch. There are two tramways within the Arch, one at the north end, and the other at the south end. The entry doors have windows, so people traveling within the Arch are able to see the interior structure of the Arch during the ride to and from the observation deck.
New city hall, Hannover, GermanyThe elevator in the new city hall in Hannover, Germany is a technical rarity, and unique in Europe, as the elevator starts straight up, but then changes its angle by 15 degrees to follow the contour of the dome of the new city hall in Hannover. The cabin therefore tilts 15 degrees during the ride. The elevator travels a height of 43 meters. The new city hall was built in 1913. The elevator was destroyed in 1943 and rebuilt in 1954. Luxor InclinatorIn Las Vegas, Nevada, at the Luxor Casino, is the Inclinator. The shape of this casino is a Pyramid. Therefore, the elevator travels up the side of the pyramid at a 39 degree angle.
Fourth Street elevator
The Fourth Street Elevator is located in Dubuque, Iowa. Also known as the Fenelon Place Elevator, it is the shortest and steepest railroad in the world. This elevator carries passengers from the bottom of one of the major bluffs in Dubuque to the top and back. The elevator is listed in the National Register of Historic Places. The elevator is 296 feet (90 m) long, with a vertical elevation of 189 feet (58 m). The elevator is Funicular in design. There are two cars that always start out opposite each other, and pass each other at the mid-point of the elevator. The two cars in the cable-driven railway are powered by an engine in the station house at the top of the hill. The engine only needs to overcome inertia and compensate for the varying weight of the passengers in the cars. Because the design is funicular, the cars counterbalance each other, and the weight of the two cars does much of the work in moving them back and forth. The weight of the car going down the bluff helps pull the other car at the bottom up to the top. Local businessman J.K. Graves built an elevator in 1882 to carry him from his home at the top of the bluff to his office at the bottom. This saved a considerable amount of time - during the 19th century it took at least half an hour to get from one end of the bluff to the other. Eventually Graves gave his neighbors rides on the elevator. In 1884 the first elevator was destroyed by fire. Graves rebuilt the elevator, opened it to the public and charged admission. The second elevator lasted until 1893, when it was destroyed by fire. Graves was unable to rebuild the elevator, so a number of his neighbors banded together and formed the Fenlon Place Elevator Company. They built the present elevator, which is still in service today. Even though the elevator is no longer a daily necessity for neighbors since the rise of the automobile, it is still a popular tourist attraction and a unique part of the city. Downtown Dubuque can be seen from the observation deck, as well as the Mississippi River, and the states of Illinois and Wisconsin. Manufacturers of elevators
See also |
This page is based on the Wikipedia article ''Elevator''. It is licensed under the GNU free documentation license.